Our patented Inlet Gas-Free cover saves money from additional openings on the deck
Principle:
U-ISO-HV series of high velocity Tank Venting valves are non-hammering, non-oscillating, non-accumulating of condensate and non-corrosive for marine cargo tanks with simple operation and technically advanced designs.
Benefits & Credentials:
Besides preventing hull and tank stress due to over and under pressure during loading and unloading of liquid cargo, the ISO series is also designed to prevent the flame passage into cargo tanks.
This complies to IMO MSC/Circ. 677/1009, ISO 15364 and vapor control system of USCG (46 CFR.39-20.11 & 162.017).
Crude Oil Tankers
Product Tankers
Chemical /Oil Tankers
Floating Production and Storage Offloading (FPSO)
Shuttle Tankers
Tank Farms
Regulation V/15-1(B)
Since 1996, January 1, all tankers exceeding 20,000 DWT are to have an emergency towing arrangement fitted at the aft and forward.
This IMO resolution MSC35(63) which covers the installation of emergency towing arrangements on tankers was decreed after the unfortunate disaster of the MV Braer in 1993.
KETA-40A & 20A on deck type
- Installation on deck type at AFT of ship.
- Applied to ship of over 20,000 DWT tankers.
- Safe working load (S.W.L.) - 1000 KN and 2000 KN
- Tested strength load - 2000 KN and 4000 KN,
KETA-40F on deck & Bulwark type
- Installation - On deck & bulwark type, at Forward of ship
- Applied to ship of over 20,000 DWT tankers.
- Safe working load (S.W.L.) 1000KN and 2000KN
- Tested strength load - 4000KN
Principle: DIGITAL SYSTEM Detection of Ullage
Ultrasonic method - Liquid filled in the gap between two piezoelectric transducers carries the vibrations from the transmitter to the receiver and activates an electronic switch to indicate "OIL" and changes the beeping tone be intermittent.
Detection of Interface
Two electrodes are used to measure the electrical resistance of water, which is many times lower than oil. This conductivity of water let the electrical current through and triggers a switch to indicate "WATER" and changes the beeping tone to continuous.
Temperature measurement
Temperature is measured simultaneously without playing with the switch. The sensing element is a PT100 RTD (Resistance Temperature Detector) sensor embedded inside the electrode. It is constantly monitoring while the ullage and interface levels are determined.
Ullage space environment - displays temperature and "GAS" with intermittent beep sound.
Sensor touches the Oil surface - displays temperature and "OIL" with frequent beep sound.
Further down into the tank if there is water phase - displays temperature and "WATER" with continuous beep sound.
The TFC-01 Advantage
- Displays OIL/GAS/WATER and temperature at same time
- Linear temperature resistance curve enables auto-calibration and high accuracy at display
- Complies to IMO Resolution MEPC5 (XII) type class approvals: USCG, ABS, DnV, BV, RR and KR
- Intrinsically safe circuits: IEC 60079-0 & 60079-11 Ex ia IIB T4 standard Exia IIB T4
- Employs the latest technology - PIC micro controllers
- Low battery energy monitoring and display
- Ultrasonic and Conductivity methods - most reliable and accepted
- PT100 temperature sensor giving standard output BS 1904, IEC751 JMS type E and DIN43760 working on Alpha = 0.00385
- Adaptors available for connection to 2 main competitors, vapor valves
- Programmable in accordance to user's need
- Single on-off switch leaves no room for human error
- Multi-tasking, performing various tasks at the same time
- Gas-tight version - one tape for both chemical and crude oil application
- Fast multiplexer - executing one million instructions per second
APPLICATIONS:
Ship of all types, e.g. containers, bulk carriers, general cargo vessels, gas carriers, crude oil tankers, product/chemical tankers, ro-ro vessel, supply vessels, and FPSO. Naval vessels and military ships.
Underground tunnels, subway stations, trains, Chemical Processing Plants, Refineries, Warehouses, factories and office buildings.
BACKGROUND
The main idea behind local fire protection is to achieve immediate activation of the extinguishing elements without having to evacuate the machine space, or to stop ventilation fans, close doors and openings and to provide early suppression of a fire in areas which are considered to be of a potential fire hazard.
The IMO regulation requires all passenger vessels built before April 1980 to be retrofitted with the mist spray protection from extinguishing systems using: Halon 1301, 1211, and 2401 and Perfluorocarbons, which were prohibited for new installations.
SOLAS Ch. II-2 Reg.7.7 IMO Res. A800
1. Passenger ships of 500 gross tonnage and above constructed on or after July 2002.
2. Passenger ships of 2000 gross tonnage and above constructed before 1 July 2002.
All installations of the Fixed Water-Based Local Application Fire Fighting System should be installed by 1 October 2005. Applications include Category A Machinery Spaces, Accommodation, Public Spaces and Service Area.
MCS Cir. 913
Local Application Fire Fighting Systems for use in Category A Machinery Spaces. All types of vessels, including passenger ships.
MCS Cir. 668 and 728
Alternative arrangements for Halon fire-extinguishing systems in machinery spaces of category A and cargo pump-rooms. All types of vessels.
Today, water mist systems can provide a reasonable solution for those affected by either mandate. Water mist systems are also known to be effective against fires involving ordinary combustibles, gas jet fires, flammable liquid pool and spray fires including electrical hazards.